Saturn Outlook Cooling Fan Relay Replacement at your home or office.

Our mobile mechanics offer services 7 days a week. Upfront and transparent pricing.

Estimate price near me

Service Location

Customer Ratings

(74)

Included for free with this service

Online Booking

Mechanic comes to you

12-month / 12k-mile warranty

Free 50 point safety inspection

Our certified mobile mechanics can come to your home or office 7 days a week between 7 AM and 9 PM.

Customer Ratings

(74)

Cooling Fan Relay Replacement Service

How much does a Cooling Fan Relay Replacement cost?

On average, the cost for a Saturn Outlook Cooling Fan Relay Replacement is $114 with $19 for parts and $95 for labor. Prices may vary depending on your location.

CarServiceEstimateShop/Dealer Price
2010 Saturn OutlookV6-3.6LService typeCooling Fan Relay ReplacementEstimate$195.95Shop/Dealer Price$226.19 - $294.41
2007 Saturn OutlookV6-3.6LService typeCooling Fan Relay ReplacementEstimate$133.35Shop/Dealer Price$152.96 - $189.24
2009 Saturn OutlookV6-3.6LService typeCooling Fan Relay ReplacementEstimate$175.95Shop/Dealer Price$206.21 - $274.44
2008 Saturn OutlookV6-3.6LService typeCooling Fan Relay ReplacementEstimate$175.95Shop/Dealer Price$206.19 - $274.40
Show example Saturn Outlook Cooling Fan Relay Replacement prices

What is the Cooling Fan Relay all about?

Modern vehicles employ electric cooling fans to draw air into the engine compartment, through the radiator, and into the air conditioning condenser. This action removes heat from the coolant in the radiator and pulls heat from the refrigerant in the air conditioning condenser. The electric cooling fan is an electric motor with fan blades attached to it. It turns on when the powertrain control module receives a signal that the temperature of the engine or air conditioning warrants the extra flow of air.

The powertrain control module then sends a signal for the cooling fan relay to supply power to the cooling fan. The fan motor relay performs the action of a switch, sending 12-volt power to the cooling fan and initiating its operation. Once the engine temperature drops below the threshold programmed into the powertrain control module, the cooling fan turns off. In some makes and models, the cooling fan can continue running after the engine has been shut off, or it can turn on while the ignition is off. If the cooling fan relay is faulty, the cooling fan can continue to run unnecessarily, even when the ignition is off and the engine is cold. Conversely, the cooling fan may not run at all causing the engine to overheat. Since the cooling fan plays a factor in air conditioning performance, your air conditioning may not blow cold air.

Keep in mind:

  • The cooling fan can run even with the ignition off. Use caution when working in and around the cooling fan to prevent personal injury.
  • Some vehicles are equipped with two cooling fans, with separate cooling fan relays controlling each one.

How it's done:

  • The Cooling Fan Relay is verified that it needs to be replaced. The main access relay panel is open to access the cooling fan relay.

  • The defective Cooling Fan Relay is removed from the relay box by pulling straight up and out of the connection.

  • The connection is checked for any damage or overheating. The new Cooling Fan Relay is installed by lining up the pins and pressing it into the connection.

  • The Cooling Fan Relay is tested for operation by running the engine or turning on the A/C.

  • The vehicle is tested for proper operation of the Cooling Fan during a road test.

Our recommendation:

The cooling fan relay is meant to last indefinitely, but as with all electrical components, it can fail prematurely. There are no preventative measures you can take against its failure. If your engine temperature rises into the red zone, or if the cooling fan won’t quit operating, have one of our expert technicians diagnose the problem and replace the cooling fan relay if required.

What common symptoms indicate you may need to replace the Cooling Fan Relay?

  • Engine temperature runs higher than normal or overheats
  • Air-conditioning does not function
  • Cooling fan continues to run indefinitely

How important is this service?

The electric cooling fan plays an important role to control engine temperature. In a situation where the cooling fan will not turn on, overheating and engine damage can occur. If the cooling fan runs continuously, the fan motor can burn out or electrical drain can deplete your battery. If the cooling fan relay is faulty, have it replaced as soon as possible to prevent additional, expensive repairs.

Fast and easy service at your home or office

Backed by 12-month, 12.000-mile guarantee


Meet some of our expert Saturn mechanics

Real customer reviews from Saturn owners like you.

Excellent Rating

(74)

Rating Summary
70
3
1
0
0
70
3
1
0
0

Pedro

31 years of experience
78 reviews
Pedro
31 years of experience
Saturn Outlook V6-3.6L - Electric Problems - Tinley Park, Illinois
Very informative in regard to the work done and future work needed. Great customer service and price!

Jason

22 years of experience
20 reviews
Jason
22 years of experience
Saturn Outlook V6-3.6L - Coolant is leaking - St. Leo, Florida
He was very professional.

John

27 years of experience
1019 reviews
John
27 years of experience
Saturn Outlook V6-3.6L - Power Steering Pump - Houston, Texas
John has shown himself to be trustworthy and honest. He has offered great advice as well as excellent service.

Jacob

15 years of experience
74 reviews
Jacob
15 years of experience
Saturn Outlook V6-3.6L - Power Steering Pressure Hose - Grayson, Georgia
Great experience with Jacob...very helpful and courteous.

Excellent Rating

(74)

Rating Summary
70
3
1
0
0
70
3
1
0
0
Number of Saturn Outlook services completed
814+
services done by our mechanics
TOTAL NUMBER OF EXPERT Saturn MECHANICS
700+
experts on our platform

Recent articles & questions

The Top 5 Selling Cars in Arkansas in 2012
Arkansas, Arkansas, like many other states, has to deal with a wide range of weather, from the stifling to the icy. This means drivers need vehicles that can handle the heat while also helping them get through slippery conditions. In...
P2281 OBD-II Trouble Code: Air Leak Between Mass Airflow (MAF) Sensor and Throttle Body
Diagnostic Diagnostic Trouble Code (DTC): P2281 P2281 code definition Air Leak Between Mass Airflow (MAF) Sensor and Throttle Body Related Trouble Codes: P2282 : Air Leak Between Throttle Body and Intake Valves Engine Misfire Codes that may be a symptom...
Industry News for Automotive Techs: August 3-9
VW is caught cheating even more on emissions tests, PTEN names top 2016 automotive innovations, aluminum goes mainstream on the new F-150, and more.

Pops and misfires, what would make this happen?

The Check Engine light coming on is an indication that continued operation could cause damage. The engine could also emit excessive emissions. You should have the vehicle's computer scanned for codes. This test will confirm that when the light is...

My car consumes fuel excessively

Hello there. Many faults could cause your vehicle to consume excessive fuel. The most common faults are a misfire condition (https://www.yourmechanic.com/services/engine-is-misfiring-inspection), a bad mass airflow (MAF) sensor (https://www.yourmechanic.com/services/mass-airflow-sensor-replacement), a fuel leak (https://www.yourmechanic.com/services/fuel-is-leaking-from-gas-tank-inspection), a vacuum leak, a faulty oxygen sensor (https://www.yourmechanic.com/services1/oxygen-sensor-replacement),...

Smoke coming from the tail pipe when I accelarate. Burning oil.

Blue smoke coming from the exhaust generally means that the motor is burning the engine oil. This can happen for a couple of different reasons such as worn piston rings or leaking valve guide seals. When this happens, the engine...

How can we help?

Our service team is available 7 days a week, Monday - Friday from 6 AM to 5 PM PST, Saturday - Sunday 7 AM - 4 PM PST.

1 (855) 347-2779 · hi@yourmechanic.com